ST-EG100-E Installation and User Guide Virtual Keypad
ON/OFF Status Button - Shows the current state (on = green, off = grey) of the
associated lighting component. Clicking on the indicator will toggle the current state
of the component.
Dimmer Slider - Adjusts the brightness of the associated lighting component. This
functionality is applicable only to dimmer type components, otherwise, setting to zero
will turn off the component and any non-zero value will turn the component on.
Timer Enable Checkbox - All checked components will be configured to turn on/off
for the specified amount of time.
Toggle device state (Automatic on/off time) - Allows checked components to be
turned on/off for the specified amount of time. The maximum supported time is 2
hours, 46 minutes and 39 seconds (9999 seconds).
Set Time Button - Requests the checked components be turned on/off for the
specified amount of time.
4.4.3. Climate Page
The climate display shows the current state of thermostats interfaced to the system and allows
control of the thermostat settings. By default, the first defined thermostat is displayed. An option
menu allows the selection of different thermostats for display and control, if installed. The
current temperature is displayed, along with the thermostat operating mode, fan setting, and
heating and cooling set points.
The thermostat operating mode and fan setting may be modified by selecting a new value from
the drop down menus. The heating and cooling set points may be changed by using the up/down
arrows to raise/lower the set point.