ST-EG100-E Installation and User Guide Virtual Keypad
The valid modes for the thermostat operation are thermostat dependent, however, typically, they
are “Off”, “Heat”, “Cool”, “Auto”, and “Emergency Heat”. The valid modes for the fan are
“Off”, “On”, and “Auto”. Note: the fan “Off” state is only valid if the thermostat mode is “Off”.
4.4.3.1. Thermostats
Thermostats - Presents a list of available thermostats connected to the system.
Temperature - Ambient temperature of the currently selected thermostat.
Humidity - Relative humidity of the currently selected thermostat (Omnistat2
only).
Outside – Remote Probe temperature of the currently selected thermostat
(Omnistat2 only).
Heat/Cool Setpoint - Temperature at which the associated system will be
activated.
Mode - Selects the thermostat control mode.
¾ Off - Disables climate control.
¾ Heat - Prevents the ambient temperature from falling below the
heating setpoint.
¾ Cool - Prevents the ambient temperature from rising above the cooling
setpoint.
SETECH Security & Automation Revision 1
96-300001 Page 31 of 44